Pune, Maharashtra
Leading Wholesaler, Retailer, Trader, Distributor and Importer of 2100T Modbus Gateway, CP202-2CI Gateway, MB-100-RS232 Gateway, MB-50 Gateway, NL 50 MPI Gateway, NT 100-RE-DP Gateway, NT 100-RE-EN Gateway, NT 151-RE-RE Gateway, NT 50 DP-EN Gateway, NT 50 DP-RS Gateway, NT 50 RS-EN Gateway and NT 50-CO-EN Gateway from Pune.
Business Type | Exporter, Importer |
Brand Name | Planet |
Preferred Buyer From
Location | Anywhere in India |
Standard Industrial Modbus TCP/RTU/ASCII Network Integration
PLANET has added the Industrial Modbus TCP/IP Protocol to its easily-integrated industrial management level products that come with SCADA/HMI system and other data acquisition systems on factory floors. Moreover, the industrial IT SNMP network is upgraded to the Industrial automation Modbus TCP/IP network. PLANET industrial management level products with the Modbus TCP/IP Protocol offer flexible network connectivity solutions for the industrial automation environment.
To complete the industrial automation environment application solution, PLANET has announced a first industrial level 1-port RS232/422/485 Modbus Gateway, IMG-2100T, a bridge that converts between Modbus TCP/IP Protocol and Modbus RTU/ASCII Protocol. It features a wide operating temperature range from -40 to 75 degrees C and a compact but rugged IP30 metal housing.
Features
Serial Interface
Ethernet Interface
Management Function
Industrial Case and Installation
- 9 to 48V DC / 24V AC, redundant power with reverse polarity protection
-40 to 75 degrees C operating temperature
Business Type | Exporter, Importer |
Preferred Buyer From
Location | Anywhere in India |
CP202-2CI is a CAN server that has integrated 2 CAN ports and 1 Ethernet port. It can implement interconnection between CAN-Bus network and Ethernet to further extend the communication range of CAN-Bus network. This product supports 2 CAN to 1 100M Ethernet copper port and adopts wall mounting which can meet the requirements of different scenes.
CAN server supports multiple network protocols, such as TCP, UDP, TELNET, ARP, ICMP, HTTP, DNS and DHCP protocols. It possesses complete management function, like access control, quick configuration, online upgrade, etc. Each CAN supports 4 TCP or UDP sessions, and multiple operating modes like TCP Server, TCP Client, UDP Server, UDP Client, UDP Rang and UDP Multicast. Access methods such as TELNET, WEB are also supported. The network management system could bring you great user experience via its friendly interface design and easy and convenient operation.
DEF button could implement restoring to factory setting for device. Hardware adopts fanless, low power consumption, wide temperature and voltage design and has passed rigorous industrial standard tests, which can suit for the industrial scene environment with harsh requirements for EMC. It can be widely used in PLC control and management, building automation, healthcare automation system, measuring instrument and environment monitoring system, etc.
Features and Benefits :
Specifications
Ethernet | Standard: 10Base-T, 100Base-TX |
Protocol: TCP, UDP, ARP, HTTP, TELNET, ICMP, DHCP, DNS | |
Rate: 10/100M Automatic Flow Control, MDI/MDI-X Autotunning | |
Interface quantity: 1 | |
Interface form: RJ45 | |
Duplex mode: Self-adaptive Full/Half Duplex Mode | |
Operating mode: 4 sessions, support operating modes like TCP Server, TCP Client, UDP Server, UDP Client, UDP Rang and UDP Multicast | |
CAN Interface | Standard: CAN2.0A, CAN2.0B |
Interface quantity: 2 CAN ports | |
CAN signal: CANH, CANL | |
Duplex mode: 2-wire Half Duplex Mode | |
Baud rate: 5kbps~1000kbps | |
Load capacity: support concurrent transmitting of 110 nodes | |
Transmission distance: 40m~10km | |
Interface form: adopt 10-pin 5.08mm pitch terminal blocks | |
Terminating resistor: optional built-in 120Ω terminating resistor | |
Interface protection: 2kVAC isolation protection | |
Configuration Method | WEB configuration management, TELNET configuration, Windows configuration tool |
Security | Classification of User Permissions, IP Address Filtering, MAC Address Filtering |
LED Indicator | Power supply indicator, Ethernet port indicator, CAN running indicator, CAN error indicator |
Power Requirement | 9~24VDC |
4-pin 5.08mm pitch terminal blocks | |
Power Consumption | No-load: 1.0W@12VDC |
Full-load: 1.1W@12VDC | |
Environmental Limit | Operating temperature: -40~75℃ |
Storage temperature: -40~75℃ | |
Relative humidity: 5%~95%(no condensation) | |
Physical Characteristic | Housing: IP40 protection, metal |
Installation: wall mounting | |
Dimension (W x H x D): 70.6mm×94mm×26mm | |
Weight: 253g | |
Industrial Standard | IEC 61000-4-2 (ESD, electrostatic discharge), Level 3 |
Air discharge: ±8kV | |
Contact discharge: ±6kV | |
IEC 61000-4-4 (EFT, electrical fast transient pulses), Level 3 | |
Power supply: ±2kV | |
Ethernet port: ±1kV | |
CAN port: ±2kV | |
IEC 61000-4-5 (Surge), Level 3 | |
Power supply: common mode±2kV, differential mode±1kV | |
Ethernet port: ±2kV | |
CAN port: common mode±2kV, differential mode±1kV | |
Shock: IEC 60068-2-27 | |
Free fall: IEC 60068-2-32 | |
Vibration: IEC 60068-2-6 | |
Certification | CE, FCC, RoHS |
Warranty | 3 years |
Business Type | Exporter, Importer |
Brand Name | Viltrus |
Download | ![]() |
Preferred Buyer From
Location | Anywhere in India |
M-Bus to Modbus (RS485) Converter
M-Bus to Modbus RTU (RS485) Converter is dedicated to convert M-Bus signal to Modbus (RS485) and to allow M-Bus devices to communicate on a Modbus network.
The M-Bus is a bus optimized for the reading of measurement instruments like energy meters, hot and cold water meters, gas, pressure, sensors and actuators, etc. Nowadays, more and more manufacturers implement the M-Bus interface in their meters, making it the ideal basis for remote reading and smart metering applications.
Main features:
Device versions:
Technical features:
Business Type | Exporter, Importer |
Brand Name | Viltrus |
Preferred Buyer From
Location | Anywhere in India |
M-Bus to Modbus (RS485) Converter
M-Bus to Modbus RTU (RS485) Converter is dedicated to convert M-Bus signal to Modbus (RS485) and to allow M-Bus devices to communicate on a Modbus network.
The M-Bus is a bus optimized for the reading of measurement instruments like energy meters, hot and cold water meters, gas, pressure, sensors and actuators, etc. Nowadays, more and more manufacturers implement the M-Bus interface in their meters, making it the ideal basis for remote reading and smart metering applications.
Main features:
Device versions :
Technical features :
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
As directly mountable or firmly attachable DIN rail device, the adaptors netLINK-MPI and netTAP-MPI replace expensive CP communication processors. The adaptors allow the programming, the visualization and the control of S7-200®, S7-300® or S7-400® PLCs via Ethernet.
The provided driver integrates into all well-known SIMATIC S7® engineering tools like STEP7® or TIA portal as a PG/PC programming interface. The device is set up with the engineering tool or conventional web browsers via the integrated web configuration pages.
The adaptors are suitable to program or change S7-PLC control programs and may serve to engineer HMI devices with the visualization software WinCC. By supporting the ”ISO on TCP“ RFC1006 Ethernet protocol, any third party or SIMATIC® visualization station can be coupled to the PLC. Once integrated into the office or plant network and connected to the internet, remote maintenance and logging over a router are also possible since plain TCP/IP protocol access mechanisms are used.
Organized in a network, direct communication between two or several PLCs via Ethernet can be realized. Even a coupling of PLCs without Ethernet port is possible using two adapters in conjunction. Fully integrated PROFIBUS diagnostics and Master Class 2 DPV1 services allow the unrestricted DP Slave device configuration and parameterization in STEP7®.
Power is supplied by a 24 V DC connector. If supported by the S7 PLC, the netLINK-MPI adaptor may be powered via the D-Sub9 connector and its extra feed-through D-Sub9 connector allows the connection of further devices to the same MPI/DP network.
Details :
Specifications
Product | Product name | NL 50-MPI |
Part number | 1701.43 | |
Brief description | S7-200/300/400 Ethernet Programming Connector | |
Function | Monitoring, programming and visualizing S7-PLCs over Ethernet | |
Communication controller | Type | netX 50 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial flash, with boot loader, firmware und configuration | |
Power supply | Supply voltage | 24 V DC ± 6 V DC |
Current (typically) | 57 mA (at 24 V), 72 mA (at 18 V), 48 mA (at 30 V) | |
Connector | Connector for power supply from PLC: via D-Sub from PLC, male connector, 9-pin | |
Connector for external power supply | Mini-COMBICON socket, 3.81 mm, 2-pin | |
Communication interface 1 | Communication standard | PROFIBUS |
Interface type | RS-485, non-isolated (for hardware revision 2 and 3), isolated (from hardware revision 4) | |
Connector | D-Sub, male connector, 9-pin; D-Sub, female connector, 9-pin, as interface for a S7 programming tool with 1:1 connection | |
Communication interface 2 | Communication standard | Ethernet |
Interface type | 10BASE-T/100BASE-TX, isolated | |
Auto negotiation | supported | |
Auto cross over | supported | |
Connector | RJ45 socket | |
Displays | LED display | SYS, System status |
COM, Communication status | ||
LNK, Ethernet link status | ||
ACT, Ethernet activity status | ||
Permitted ambient conditions | Operating temperature range | 0 °C … +55 °C |
Humidity | 0 % … 85 % relative humidity (not condensing) | |
Device | Dimensions (L x W x H) | 74,3 mm x 40,6 mm x 16,7 mm |
Weight | approx. 40 g | |
Protection class | IP 20 | |
Mounting/Installation | directly on PLC | |
Configuration | Configuration software | SyCon MPI or IBHnet-Treiber |
Conformity | RoHS | yes |
Conformance with EMC directives | CE sign | yes |
Electrostatic discharge (ESD) according to IEC/EN 61000-4-2:1995 (Air discharge method) | 10 kV, Criterion A | |
Electrostatic discharge (ESD) according to IEC/EN 61000-4-2:1995 (Contact discharge method) | 4 kV, Criterion B | |
Fast transient interferences (Burst), zone B, according to IEC/EN 61000-4-4:1995 | 1 kV Power supply connectors DC, Criterion B; 1 kV Communication and data lines, Criterion A | |
Surge voltage, zone B, according to IEC/EN 61000-4-5:1995 | 1 kV CM, 0,5 kV DM Power supply connectors DC, Criterion B; 1 kV CM Communication and data lines, Criterion B |
Business Type | Exporter, Importer |
Preferred Buyer From
Location | Anywhere in India |
NetTAP 100 is the protocol converter for sophisticated conversions and supports 2-port Real-Time Ethernet to serial, Fieldbus to Fieldbus, Real-Time Ethernet to Fieldbus and Real-Time Ethernet to Ethernet conversions. It supports slave and master functionality in any combination. Master functionality is unrestricted when licensed.
A memory card slot allows the user to save firmware and configuration data on a removable card. In case of failure all that is necessary to bring the plant back on line within seconds is to move the memory card from the old netTAP 100 onto a spare unit.
Apart from standard protocols, netTAP 100 supports the creation of serial protocols with the Lua-based scripting language netSCRIPT. A full featured development environment is included within the delivery. It allows the comfortable and rapid programming of any proprietary serial protocol as well as the I/O data pre-processing during the conversion into the other field protocol.
Details :
Specifications
Product | Product name | NT 100-RE-DP |
Part number | 1712.18 | |
Brief description | Gateway Real-Time-Ethernet to PROFIBUS DP | |
Communication controller | netX | netX 100 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Memory card | Type and size | SD or MMC card, max. 2 GByte |
Power supply | Supply voltage | 24 V DC ± 6 V |
Maximum Current at 24 V (typically) | 130 mA | |
Typical power consumption | 3,2 W | |
Connector | Mini-COMBICON, 2-pin | |
Reverse voltage protection | yes | |
Requirement to the power supply | For UL conform usage: Device shall be supplied by an isolated voltage source | |
Communication interface 1 | Communication standard | Ethernet |
Interface type | 100BASE-TX or 10BASE-T, isolated | |
Connector | 2 * RJ45 | |
Communication interface 2 | Communication standard | PROFIBUS-DP |
Interface type | RS-485, optically isolated | |
Connector | D-Sub, female, 9-pin | |
Diagnostic interface | Type | USB |
Connector | Mini-USB, 5-pin | |
Displays | LED displays | SYS System status |
APL Application status | ||
COM Communication status | ||
LINK Link, ACT Activity | ||
Operating elements | Network address | Network address, 2 rotary switches |
Permitted ambient conditions | Ambient temperature (operation) | 0 … + 60 °C |
Humidity | no condensation permitted | |
Pollution degree | For UL-compliant usage: Device must be used in a pollution degree 2 environment | |
Device | Dimensions (L x W x H) | 100 x 52 x 70 mm (without connector) |
Weight | appr. 150 g | |
Degree of protection | IP 20 | |
Mounting | on DIN rail EN 60715 | |
Conformity | RoHS | Yes |
UL certification | UL | The device is UL 508 certified |
UL file | UL-File No E334100 | |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
NetTAP 100 is the protocol converter for sophisticated conversions and supports 2-port Real-Time Ethernet to serial, Fieldbus to Fieldbus, Real-Time Ethernet to Fieldbus and Real-Time Ethernet to Ethernet conversions. It supports slave and master functionality in any combination. Master functionality is unrestricted when licensed.
A memory card slot allows the user to save firmware and configuration data on a removable card. In case of failure all that is necessary to bring the plant back on line within seconds is to move the memory card from the old netTAP 100 onto a spare unit.
Apart from standard protocols, netTAP 100 supports the creation of serial protocols with the Lua-based scripting language netSCRIPT. A full featured development environment is included within the delivery. It allows the comfortable and rapid programming of any proprietary serial protocol as well as the I/O data pre-processing during the conversion into the other field protocol.
Details :
Specifications
Product | Product name | NT 100-RE-EN |
Part number | 1712.11 | |
Brief description | Gateway Real-Time-Ethernet to Ethernet | |
Communication controller | netX | netX 100 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Memory card | Type and size | SD or MMC card, max. 2 GByte |
Power supply | Supply voltage | 24 V DC ± 6 V |
Maximum Current at 24 V (typically) | 130 mA | |
Typical power consumption | 3,2 W | |
Connector | Mini-COMBICON, 2-pin | |
Reverse voltage protection | yes | |
Requirement to the power supply | For UL conform usage: Device shall be supplied by an isolated voltage source | |
Communication interface 1 | Communication standard | Ethernet |
Interface type | 100BASE-TX or 10BASE-T, isolated | |
Connector | 2 * RJ45 | |
Communication interface 2 | Communication standard | Ethernet |
Interface type | 100BASE-TX or 10BASE-T, isolated | |
Connector | 1 * RJ45 | |
Diagnostic interface | Type | USB |
Connector | Mini-USB, 5-pin | |
Displays | LED displays | SYS System status |
APL Application status | ||
COM Communication status | ||
LINK Link, ACT Activity | ||
Permitted ambient conditions | Ambient temperature (operation) | 0 … + 60 °C |
Humidity | no condensation permitted | |
Pollution degree | For UL-compliant usage: Device must be used in a pollution degree 2 environment | |
Device | Dimensions (L x W x H) | 100 x 52 x 70 mm (without connector) |
Weight | appr. 150 g | |
Degree of protection | IP 20 | |
Mounting | on DIN rail EN 60715 | |
Conformity | RoHS | Yes |
UL certification | UL | The device is UL 508 certified |
UL file | UL-File No E334100 | |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
The gateway netTAP 151 transmits IO data bidirectionally between any two industrial Real-Time Ethernet networks. It is the ideal solution for installations with heterogenous networks or such of the same kind to exchange data across given network boundaries. With more than 25 different combinations of the protocols PROFINET, EtherCAT, EtherNet/IP, POWERLINK and Sercos, the device series provides a solution for any conversion.
The integration as simple IO device into the primary network makes the converter compatible with any common PLC. On the secondary side it works either as IO device too or controls a subordinate network as a bus master. The length of the IO data can be scaled to any application and the data in between can be mapped on byte level arbitrarily.
Secure network separation is provided by two Ethernet controllers, each connected to a Dual Ethernet port with integrated switch. That allows realizing star, ring and inline network topologies without further peripherals. Both controllers handle the protocols independent from each other and exchange only the IO data across a data buffer. An overall data processing time lower than 10 milliseconds is achieved.
The devices can be ordered preloaded with firmware and license or unloaded. Unloaded devices minimize the storage costs. Subsequent loading of a firmware configures these devices for any conversion most flexible. All devices are commissioned and diagnosed network independent over USB.
Details :
Specifications
NT 151-RE-RE | Parameter | Value |
Product | Part number | 1722.122 |
Brief description | Gateway Real-Time Ethernet Slave to Real-Time Ethernet Slave | |
Communication controller | Primary network X2 / Secondary network X3 | netX 51 / netX 100 |
Integrated Memory | RAM | netX 51: 8 MB SDRAM, netX 100: 8 MB SDRAM |
FLASH | netX 51: 4 MB serielles Flash, netX 100: 4 MB serielles Flash | |
SD memory card (optional) | max. 2 GByte, do not use SDHC or SDXC card types | |
Power supply | Supply voltage | 24 V DC ± 6 V |
Current at 24 V (typically) | 190 mA | |
Power consumption | 4.78 W | |
Connector | MINI COMBICON, 5-pin | |
Reverse voltage protection | yes | |
Communication interface X2 | Communication standard | Ethernet |
Interface type | 100BASE-TX, isolated | |
Connector | 2 * RJ45 | |
Auto negotiation | supported | |
Auto cross over | supported | |
Communication interface X3 | Communication standard | Ethernet |
Interface type | 100BASE-TX, isolated | |
Connector | 2 * RJ45 | |
Auto negotiation | supported | |
Auto cross over | supported | |
Diagnostic interface | Type | USB |
Connector | Mini-USB, 5-pin | |
Displays | LED displays | SYS system status |
APL application status | ||
COM0, COM1, COM2, COM3 protocol specific communication status | ||
4 x LINK (RJ45) | ||
4 x ACT (RJ45) | ||
Permitted ambient conditions | Ambient temperature range for operation | If distance to neighboring devices is minimum 17.5 mm: -20 … +60°C; If housing has contact to neighboring device (and if surface temperature of neighboring device does not exceed +70°C): -20 … +50°C |
Humidity | 10 ... 95 %, no condensation permitted | |
Device | Dimensions (L x W x H) | 113.6 mm x 22.6 mm x 99 mm (without connector) |
Weight | 121 g | |
Degree of protection | IP20 | |
Mounting | Top hat rail (DIN rail EN 60715) | |
Configuration | Software | SYCON.net |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
ESD Air discharge (DIN EN 61000-4-2) | 8 kV (criterion A) | |
ESD contact discharge (DIN EN 61000-4-2) | 6 kV (criterion A) | |
Immunity: radiated, HF field (DIN EN 61000-4-3) 80 MHz ... 3 GHz | 10 V/m (criterion A) | |
Burst (DIN EN 61000-4-4) | 2.2 kV (criterion B) | |
Surge (DIN EN 61000-4-5) | 1 kV (criterion A) | |
Immunity: conducted (DIN EN 61000-4-6) 150 kHz ... 80 MHz | 10 V/m (criterion A) | |
Radio interference emission (DIN EN 55016-2-3) | 30 ... 2000 MHz (criterion A) | |
Radio interference voltage (DIN EN 55016-2-1) | 0.01 ... 30 MHz (criterion A) |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
NetTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network.
The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities makes netTAP 50 an attractive gateway in terms of price and universality.
Details :
Specifications
Product | Product name | NT 50-DP-EN |
Part number | 1758.11 | |
Brief description | Gateway PROFIBUS DP to Ethernet | |
Communication controller | Communication controller | netX 50 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Power supply | Supply voltage | 24 V ± 6 V DC |
Current consumption at 24 V (typically) | 72 mA / 150 mA (with short circuit at the output of PROFIBUS) | |
Typical power consumption | 1,8 W | |
Connector type | Mini-COMBICON, 2-pin | |
Communication interface 1 | Communication interface | PROFIBUS DP |
Interface type | RS-485, optically isolated | |
Connector type | D-Sub female, 9-pin | |
Communication interface 2 | Communication interface | Ethernet |
Interface type | 100 BASE-TX or 10 BASE-T, isolated | |
Connector type | 1 * RJ45 | |
Diagnostic interface | Type | Ethernet, 4-pin |
Connector type | RJ45 socket | |
Display | Display 1 | SYS System status |
Display 2 | APL Application status | |
Display 3 | COM Communication status | |
Display 4 | LINK Link, ACT Activity | |
Permitted ambient conditions | Ambient temperature (operation) | 0 … +60 °C |
Relative humidity (operation) | no condensation allowed | |
Device | Dimensions (L x W x H) | 100 x 26 x 66 mm (without connector) |
Weight | appr. 80 g | |
Degree of protection | IP 20 | |
Mounting type | on DIN rail EN 60715 | |
Configuration | Configuration software | SYCON.net |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
netTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network.
The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities makes netTAP 50 an attractive gateway in terms of price and universality.
Details :
Specifications
Product | Product name | NT 50-DP-RS |
Part number | 1758.1 | |
Brief description | Gateway PROFIBUS DP to RS-232/422/485 | |
Communication controller | Communication controller | netX 50 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Power supply | Supply voltage | 24 V ± 6 V DC |
Current consumption at 24 V (typically) | 72 mA / 150 mA (with short circuit at the output of PROFIBUS) | |
Typical power consumption | 1,8 W | |
Connector type | Mini-COMBICON, 2-pin | |
Communication interface 1 | Communication interface | PROFIBUS DP |
Interface type | RS-485, optically isolated | |
Connector type | D-Sub female, 9-pin | |
Communication interface 2 | Communication interface | Serial interface |
Interface type | RS-232, RS-422, RS-485 | |
Connector type | RJ45, Ethernet and serial interface together in one connector | |
Diagnostic interface | Type | Ethernet, 4-pin |
Connector type | RJ45 socket | |
Display | Display 1 | SYS System status |
Display 2 | APL Application status | |
Display 3 | COM Communication status | |
Display 4 | LINK Link, ACT Activity | |
Permitted ambient conditions | Ambient temperature (operation) | 0 … +60 °C |
Relative humidity (operation) | no condensation allowed | |
Device | Dimensions (L x W x H) | 100 x 26 x 66 mm (without connector) |
Weight | appr. 80 g | |
Degree of protection | IP 20 | |
Mounting type | on DIN rail EN 60715 | |
Configuration | Configuration software | SYCON.net |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
netTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network.
The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities makes netTAP 50 an attractive gateway in terms of price and universality.
Details :
Specifications
Product | Product name | NT 50-RS-EN |
Part number | 1750.11 | |
Brief description | Gateway RS-232/422/485 to Ethernet | |
Communication controller | Communication controller | netX 50 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Power supply | Supply voltage | 24 V ± 6 V DC |
Current consumption at 24 V (typically) | 72 mA | |
Connector type | Mini-COMBICON, 2-pin | |
Communication interface 1 | Communication interface | Serial Interface |
Interface type | RS-232, RS-422, RS-485 | |
Connector type | RJ45, Ethernet and serial interface together in one connector | |
Communication interface 2 | Communication interface | Ethernet |
Interface type | 100 BASE-TX or 10 BASE-T, isolated | |
Connector type | 1 * RJ45 | |
Diagnostic interface | Type | Ethernet, 4-pin |
Connector type | RJ45 socket | |
Display | Display 1 | SYS System status |
Display 2 | APL Application status | |
Display 3 | COM Communication status | |
Display 4 | LINK Link, ACT Activity | |
Permitted ambient conditions | Ambient temperature (operation) | 0 … +60 °C |
Relative humidity (operation) | no condensation allowed | |
Device | Dimensions (L x W x H) | 100 x 26 x 66 mm (without connector) |
Weight | appr. 80 g | |
Degree of protection | IP 20 | |
Mounting type | on DIN rail EN 60715 | |
Configuration | Configuration software | SYCON.net |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Business Type | Exporter, Importer |
Brand Name | Hilscher |
Preferred Buyer From
Location | Anywhere in India |
netTAP 50 is a protocol converter for simple conversions. netTAP 50 converts 1-port Real-Time Ethernet, fieldbus and serial automation protocols. Slave to slave or slave to master conversions are supported. As a master, netTAP 50 provides full master functionality to one slave device only. This makes it easy to integrate a single field device into any higher-level network.
The design impresses with a cost-optimized, compact hardware implementation being reduced to the elementary requirements of a protocol converter. The converter addresses market segments which set the focus on cost savings. The cost-reduced design combined with its countless conversion possibilities makes netTAP 50 an attractive gateway in terms of price and universality.
Details :
Specifications
Product | Product name | NT 50-CO-EN |
Part number | 1756.11 | |
Brief description | Gateway CANopen to Ethernet | |
Communication controller | Communication controller | netX 50 |
Integrated Memory | RAM | 8 MB SDRAM |
FLASH | 4 MB serial Flash | |
Power supply | Supply voltage | 24 V ± 6 V DC |
Current consumption at 24 V (typically) | 72 mA | |
Connector type | Mini-COMBICON, 2-pin | |
Communication interface 1 | Communication interface | CANopen |
Interface type | ISO 11898, optically isolated | |
Connector type | D-Sub male, 9-pin | |
Communication interface 2 | Communication interface | Ethernet |
Interface type | 100 BASE-TX or 10 BASE-T, isolated | |
Connector type | 1 * RJ45 | |
Diagnostic interface | Type | Ethernet, 4-pin |
Connector type | RJ45 socket | |
Display | Display 1 | SYS System status |
Display 2 | APL Application status | |
Display 3 | COM Communication status | |
Display 4 | LINK Link, ACT Activity | |
Permitted ambient conditions | Ambient temperature (operation) | 0 … +60 °C |
Relative humidity (operation) | no condensation allowed | |
Device | Dimensions (L x W x H) | 100 x 26 x 66 mm (without connector) |
Weight | appr. 80 g | |
Degree of protection | IP 20 | |
Mounting type | on DIN rail EN 60715 | |
Configuration | Configuration software | SYCON.net |
Conformity | RoHS | Yes |
Conformance with EMC directives | CE sign | Yes |
Emission | CISPR 11 Class A | |
Immunity | EN 61131-2:2003 |
Hi! Simply click below and type your query.